OUR PRODUCTS > BLOWER > DM  

 

CY125DM
CY150DM
CY190DM
CY200DM
CY230DM
CY270DM
CY275DM
CY280DM
70W, 4Pole
110W, 4P
420W, 6 P
400W, 4 pole
110W, 6 pole
350W, 6 P
3/4HP, 6 P
1/2HP, 6P
3/4HP, 6P

Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY125DM
110/220
60
1
4
0.75/0.4
70
1600
18.5
0.73
181
7.5
450
265
4.7
220
50
1
4
0.33
70
1330
12.8
0.50
126
6.3
378
222



Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY150DM
110/220
60
1
4
2/1
110
1728
27
1.06
265
14.4
864
508
5.5
220
50
1
4
1.1
110
1410
19
0.75
186
12
720
424



Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY190DM
110
60
1
4
5.7
420
1630
42
1.65
412
33.5
2010
1183
11.8
220
60
1
4
2.85
420
1630
42
1.65
412
33.5
2010
1183
220
50
1
4
2.7
420
1400
29
1.14
284
28
1680
988



Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY200DM
220
60
1
4
3.46
400
1450
55
2.17
539
37
2220
1306
12.4
220
60
1
6
1.07
110
960
25
0.98
245
26
1560
918

 

Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY230DM
110
60
1
6
5
400
1135
23
0.91
226
38
2280
1341
14.2
220
60
1
6
2.65
400
1135
23
0.91
226
38
2280
1341
220
50
1
6
2.9
400
950
16
0.63
157
32
1920
1130


Ideal for Clean Bench

Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY270DM
110
60
1
6
10
3/4HP
900
43
1.69
422
55
3300
1942
24.4
220
60
1
6
5
3/4HP
900
43
1.69
422
55
3300
1942



Ideal for Clean Bench

Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY275DM
110/220
60
1
6
7.8/4
1/2 HP
930
43
1.69
422
46
2760
1624
16.4


Ideal for Clean Bench

Model
Rated Voltage
Frequency
Phase
Pole
Current
Out Power
Speed
Max. Pressure
Max. Air Flow
Net Weight
V
Hz
Ø
P
A
W
r.p.m
mmAq
inchAq
Pa
CMM
m3/ h
CFM
KG
CY280DM
110/220
60
1
6
8/3.54
3/4HP
885
44.2
1.74
433
58
3480
2047
20.3
220
50
1
6
2.7
3/4HP
880
34.3
1.35
336
57.8
3468
2040

 

 

 

 

 

 

 

 

 

 


 

 



Tel:886-4-23322627 Fax:886-4-23322629 E-mail : blower-cy@umail.hinet.net